![ABB IRC5 with FlexPendant Operating Manual Download Page 281](http://html.mh-extra.com/html/abb/irc5-with-flexpendant/irc5-with-flexpendant_operating-manual_5099281.webp)
From - To
Bit value condition
Description
Signal name
From panel board to
main computer
1 = Chain closed
General stop, chain 2
GS2
From panel board to
main computer
1 = Soft stop enabled
Soft General stop
SOFTGSI
From panel board to
main computer
1 = Chain closed
Superior stop, chain1
SS1
From panel board to
main computer
1 = Chain closed
Superior stop, chain2
SS2
From panel board to
main computer
1 = Soft stop enabled
Soft Superior stop
SOFTSSI
From panel board to
main computer
1 = Chain closed
All switches in run
chain 1 closed
CH1
From panel board to
main computer
1 = Chain closed
All switches in run
chain 2 closed
CH2
From panel board to
main computer
1 = Enable, 0 = break
chain 1
Enable from MC (read
back)
ENABLE1
From panel board to
main computer
1 = Enable, 0 = break
chain 2
Enable from AXC1
ENABLE2_1
From panel board to
main computer
1 = Enable, 0 = break
chain 2
Enable from AXC2
ENABLE2_2
From panel board to
main computer
1 = Enable, 0 = break
chain 2
Enable from AXC3
ENABLE2_3
From panel board to
main computer
1 = Enable, 0 = break
chain 2
Enable from AXC4
ENABLE2_4
From panel board to
main computer
1 = Error, 0 = OK
Overload, panel 24V
PANEL24OVLD
From panel board to
main computer
1 = Error, 0 = OK
Overload, drive mod-
ules
DRVOVLD
From axis computer to
main computer
1 = Chain 1 closed
Read back of chain 1
after limit switches
DRV1LIM1
From axis computer to
main computer
1 = Chain 2 closed
Read back of chain 2
after limit switches
DRV1LIM2
From axis computer to
main computer
1 = K1 closed
Read back of contactor
K1, chain 1
DRV1K1
From axis computer to
main computer
1 = K2 closed
Read back of contactor
K2, chain 2
DRV1K2
From axis computer to
main computer
1 = Contactors closed
External contactors
closed
DRV1EXTCONT
From axis computer to
main computer
Toggled
A dip in run chain 1 has
been detected
DRV1TEST1
From axis computer to
main computer
Toggled
A dip in run chain 2 has
been detected
DRV1TEST2
From main computer to
panel board
1 = Set soft E-stop
Soft Emergency stop
SOFTESO
From main computer to
panel board
1 = Set soft Auto stop
Soft Auto stop
SOFTASO
From main computer to
panel board
1 = Set soft General
stop
Soft General stop
SOFTGSO
Continues on next page
Operating manual - IRC5 with FlexPendant
281
3HAC050941-001 Revision: G
© Copyright 2018 ABB. All rights reserved.
7 Handling inputs and outputs, I/O
7.4.1 Safety I/O signals
Continued
Summary of Contents for IRC5 with FlexPendant
Page 1: ...ROBOTICS Operating manual IRC5 with FlexPendant ...
Page 14: ...This page is intentionally left blank ...
Page 120: ...This page is intentionally left blank ...
Page 146: ...This page is intentionally left blank ...
Page 240: ...This page is intentionally left blank ...
Page 286: ...This page is intentionally left blank ...
Page 294: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 304: ......
Page 305: ......