Action
If Type
Output
is selected.
•
Tap to select one of the digital outputs from the list
•
Tap the
Key pressed
menu to define how the signal should behave when the
key is pressed.
•
Tap the Allow in auto menu to select if the function is also allowed in automatic
operating mode
Key pressed functions:
•
Toggle
- switches signal value from 0 to 1 or vice versa
•
Set to 1
- sets the signal to 1
•
Set to 0
- sets the signal to 0
•
Press/Release
- sets signal value to 1 while key is pressed (note that an inverted
signal will be set to 0)
•
Pulse
- the signal value pulses once
6
If Type
System
is selected.
•
Tap the
Key pressed
menu to select Move PP to main
•
Tap the
Allow in auto
menu to select if the function is also allowed in automatic
operating mode
7
Set the other keys as described in steps 3 to 7 above.
8
Tap
OK
to save the settings.
9
Operating manual - IRC5 with FlexPendant
117
3HAC050941-001 Revision: G
© Copyright 2018 ABB. All rights reserved.
3 Navigating and handling FlexPendant
3.7.2.6 Changing programmable keys
Continued
Summary of Contents for IRC5 with FlexPendant
Page 1: ...ROBOTICS Operating manual IRC5 with FlexPendant ...
Page 14: ...This page is intentionally left blank ...
Page 120: ...This page is intentionally left blank ...
Page 146: ...This page is intentionally left blank ...
Page 240: ...This page is intentionally left blank ...
Page 286: ...This page is intentionally left blank ...
Page 294: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 304: ......
Page 305: ......