Description of the BC_config_IO module
MODULE BC_config_IO(SYSMODULE,NOVIEW)
PROC BC_config_IO_proc(VAR string user_io_names{*,*})
!TPWrite "BC_config_IO_proc";
! Define your own signals. The signal
! names must be signals defined in EIO.cfg
! If 1 drive module
user_io_names{1, 1}:="BCACT1";
user_io_names{1, 2}:="BCOK1";
user_io_names{1, 3}:="BCWAR1";
user_io_names{1, 4}:="BCERR1";
! If 2 drive modules
!user_io_names{2, 1}:="BCACT2";
!user_io_names{2, 2}:="BCOK2";
!user_io_names{2, 3}:="BCWAR2";
!user_io_names{2, 4}:="BCERR2";
! If 3 drive modules
!user_io_names{3, 1}:="BCACT3";
!user_io_names{3, 2}:="BCOK3";
!user_io_names{3, 3}:="BCWAR3";
!user_io_names{3, 4}:="BCERR3";
! If 4 drive modules
!user_io_names{4, 1}:="BCACT4";
!user_io_names{4, 2}:="BCOK4";
!user_io_names{4, 3}:="BCWAR4";
!user_io_names{4, 4}:="BCERR4";
ENDPROC
ENDMODULE
Description of the EIO.cfg file
EIO:CFG_1.0:6:1::
...
#
EIO_SIGNAL:
-Name "BCACT1" -SignalType "DO"
-Name "BCOK1" -SignalType "DO"
-Name "BCWAR1" -SignalType "DO"
-Name "BCERR1" -SignalType "DO"
Continues on next page
Operating manual - IRC5 with FlexPendant
237
3HAC050941-001 Revision: G
© Copyright 2018 ABB. All rights reserved.
5 Programming and testing
5.9.6 Brake check service routine
Continued
Summary of Contents for IRC5 with FlexPendant
Page 1: ...ROBOTICS Operating manual IRC5 with FlexPendant ...
Page 14: ...This page is intentionally left blank ...
Page 120: ...This page is intentionally left blank ...
Page 146: ...This page is intentionally left blank ...
Page 240: ...This page is intentionally left blank ...
Page 286: ...This page is intentionally left blank ...
Page 294: ...This page is intentionally left blank ...
Page 298: ...This page is intentionally left blank ...
Page 304: ......
Page 305: ......