Note
Action
Move aside all cabling that is hindering access
to the axis 5 motor.
6
Shown in the figure
Remove the
motor bracket
, including the motor,
by unscrewing the two
attachment screws and
washers
.
7
Remove the timing belt of axis 5.
8
Remove the motor bracket from the motor.
9
Refitting, motor and timing belt axis 5
The procedure below details how to refit the motor and timing belt of axis 5.
Note/Illustration
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
1
Clean the mating surfaces on the motor and in
the upper arm housing.
2
3 pcs, M6 x 20.
Fit the new motor to the motor bracket, previ-
ously removed from the old motor.
3
Continues on next page
Product manual - IRB 1600/1660
291
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.6.7 Replacement of motor and timing belt, axis 5, IRB 1600
Continued