Note
Action
Tip
The spare part cable harness 3HAC027523-002 in-
cludes a galvanized coverplate without paint. If a
painted cover is prefered, use the old cover plate.
Remove the cover plate.
4
A
xx0700000114
Remove the cable pulling it out
through the passage (A).
5
Refitting, cable harness
The procedure below describes refitting of the complete cable harness.
Note
Action
Described in section
Refitting, cable harness in upper
arm housing and lower arm on page 167
Refit the cable harness.
1
Described in section
Refitting, motor axis 5 on page 299
Refit the upper arm tube.
2
Shown in figure
Location of the harness on page 172
Refit the connections in the
upper arm.
3
Pendulum Calibration is described in
Operating
manual - Calibration Pendulum
, enclosed with the
calibration tools.
Recalibrate the robot.
4
Axis Calibration is described in
Calibration method on page 349
General calibration information is included in section
.
Product manual - IRB 1600/1660
177
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness, 1600ID/1660ID
Continued
Summary of Contents for IRB 1660
Page 1: ...ROBOTICS Product manual IRB 1600 1660 ...
Page 8: ...This page is intentionally left blank ...
Page 18: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 152: ...This page is intentionally left blank ...
Page 336: ...This page is intentionally left blank ...
Page 372: ...This page is intentionally left blank ...
Page 388: ...This page is intentionally left blank ...
Page 396: ......
Page 397: ......