Note
Action
xx0700000106
Remove the hexagon nut with flange (A)
holding the two (2) clamps.
4
A Hexagon nut with flange
Disconnect R3.FB3 - R3.FB6.
5
Disconnect R3.MP3 - R3.MP6.
6
Follow instructions in section
the cable harness, IRB 1600 on page 162
.
Remove the cable harness from the lower
arm.
7
Removal, cable harness upper arm tube
The procedure below describes removal of the complete cable harness in upper
arm tube.
xx0700000099
Cover plate
A
Continues on next page
Product manual - IRB 1600/1660
175
3HAC026660-001 Revision: W
© Copyright 2006-2018 ABB. All rights reserved.
4 Repair
4.3.2 Replacing the cable harness, 1600ID/1660ID
Continued