![ABB HVC-C 100-150 kW Installation Manual Download Page 104](http://html.mh-extra.com/html/abb/hvc-c-100-150-kw/hvc-c-100-150-kw_installation-manual_2837984104.webp)
20.13
AC input specifications
20.13.1
100 kW configuration
Parameter
Specification
Input AC power connection
3-phase, 400 V AC: PE, L1, L2, L3
Input voltage range
400 VAC +/- 10%
Frequency
50 Hz +/- 4%
Maximum power dissipation
116 kVA
Power factor at full load
≥ 0.95
Efficiency
>94% and 96% in power spectrum be-
tween 20% and 100% of full power
Maximum input current
177 A AC
Nominal input current
159 A AC
Short-circuit capacity
25 kA
AC power connection
240 mm² (max.)
20.13.2
150 kW configuration
Parameter
Specification
Input AC power connection
3-phase, 400 V AC: PE, L1, L2, L3
Input voltage range
400 VAC +/- 10%
Frequency
50 Hz +/- 4%
Maximum power dissipation
174 kVA
Power factor at full load
≥ 0.95
Efficiency
>94% and 96% in power spectrum be-
tween 20% and 100% of full power
Maximum input current
265 A AC
Nominal input current
238 A AC
Short-circuit capacity
25 kA
AC power connection
240 mm² (max.)
Technical data
104