Fuses (UL)
UL fuses by Cooper Bussman for branch circuit protection per NEC per drive module are
listed below. Obey local regulations.
Fuse
Input cur-
rent (A)
ACS880-
14-…
Size
Type French Style
Type US Style
Type DIN 43653
V
A
U
n
= 500 V
1
170M4310
170M4610
170M4010
690
315
169
240A-5
2
170M5308
170M5608
170M5008
690
400
205
260A-5
2
170M5310
170M5610
170M5010
690
500
249
302A-5
3
170M6310
170M6610
170M6010
690
630
257
361A-5
3
170M6311
170M6611
170M6011
690
700
321
414A-5
3
170M6311
170M6611
170M6011
690
700
404
460A-5
3
170M6212
170M6612
170M6012
690
800
455
503A-5
U
n
= 690 V
1
170M4309
170M4609
170M4009
690
250
123
142A-7
1
170M4310
170M4610
170M4010
690
315
149
174A-7
2
170M5308
170M5608
170M5008
690
400
186
210A-7
2
170M5310
170M5610
170M5010
690
500
232
271A-7
3
170M6310
170M6610
170M6010
690
630
293
330A-7
3
170M6311
170M6611
170M6011
690
700
330
370A-7
3
170M6311
170M6611
170M6011
690
700
375
430A-7
Note:
• See also sections:
•
Protecting the drive and the input power cable in short-circuits (page 91)
•
Protecting the drive against thermal overload (page 91)
•
Protecting the input power cable against thermal overload (page 91)
• In multicable installations, install only one fuse per phase (not one fuse per conductor).
• Fuses with higher current rating than the recommended ones must not be used. Fuses
with lower current rating can be used.
• Alternative fuses can be used if they meet certain characteristics. For acceptable fuses,
see the technical note (
).
188 Technical data
Summary of Contents for ACS880-14
Page 1: ...ABB INDUSTRIAL DRIVES ACS880 14 drive modules 132 400 kW 200 400 hp Hardware manual...
Page 2: ......
Page 4: ......
Page 14: ...14...
Page 24: ...24...
Page 30: ...30...
Page 54: ...54...
Page 64: ...64...
Page 98: ...98...
Page 114: ...With twin connectors in the control panel holder 1 2 3 1 114 Electrical installation...
Page 115: ...With FDPI 02 modules OPEN TERMIN ATED 1 1 2 2 OPEN TERMINATED 3 Electrical installation 115 11...
Page 142: ...4 5 6 3 3 1 1 1 1 2 142 Installation example with full cabling panels option H381...
Page 150: ...150 Installation example with full cabling panels option H381...
Page 156: ...156...
Page 204: ...Standard configuration 204 Dimension drawings...
Page 206: ...Drive module with options 0B051 H356 0H371 206 Dimension drawings...
Page 207: ...Configuration with option H381 3AXD50000323210 Dimension drawings 207...
Page 208: ...LCL filter module 208 Dimension drawings...
Page 212: ...External control unit 3AXD50000011687 212 Dimension drawings...
Page 230: ...Declaration of conformity 230 The Safe torque off function...
Page 241: ...241...
Page 246: ...246...