Solares
TM
Smart Spa Parts Manual
CD0039
16
Rev:1121
6.
Place remaining screws in top two slots and start threading them into angle bracket until they
are almost all the way down.
7.
Pull motor assembly away from large pulley as to make belt taunt.
8.
Tighten screws to the rear of the plate down good and tight to lock the plate into position.
9.
Turn large pulley counterclockwise to verify that screw coming off pulley does not hit inductive
sensor and that sensor turns on when screw get in front of it. Adjust sensor as needed by
loosenin
g the top sensor bracket screw to achieve this if it’s out of position.
(2.5mm allen key)
10.
Connect M12 cable to stepper motor.
Docking Components
Item
Part #
Description
Item
Part #
Description
1
330277
24VDC Sealed Rotary Latch
5
350477
¼ Star Washer; SS
2
350044
¼-20 Coarse Thread Hex Nut
6
330293
Prox Sensor; 8mm x 40mm
3
350730
PH Mach Screw; ¼-20 x 1 3/8
7
350504
Dome Blind Rivet; 1/8 x 0.4
4
350751
Hex HD Screw; ¼-20 x 1 3/8