Solares
TM
Smart Spa Parts Manual
CD0039
23
Rev:1121
Power Hub
Item
Part #
Description
Item
Part #
Description
1
200449
Power Hub Assembly
3
350161
¼ Flat Washer; SS
2
350760
PH Mach Screw; ¼-20 X 3/4
4
350653
¼-20 Hex Nylock Jam Nut
Replacement Instructions
Warning! Power Hub should only be replaced by a qualified technician! Failure to connect wiring
properly could lead to electrocution, Product Malfunction, or a Fire!
1.
Unplug tub from outlet.
2.
Disconnect all connections from electrical box and disconnect all electrical box cables from other
parts of the tub. *Water level sensors can be removed by removing the two screws located
towards the bottom of the sensor.
3.
Loosen all screws on cover and remove it.
4.
Remove screws fastening electrical box to tub frame.
5.
Pull electrical box out of tub. *Cables can be removed from cable clips by pulling on lever on the
front.
6.
Install new electrical box using hardware as shown above.
7.
Make all electrical connections per drawing 08-0312. Install water level sensors in brackets on
the side of the tub. Tighten down sensor in the center of its adjustment range and adjust as
needed.
8.
Connect electrical box to power and test thoroughly to ensure all connection were made
correctly. The inputs/ outputs screen will help with this as most inputs can be isolated and most
outputs can triggered from there. Any other items will have to be tested through conducting
their functions.