Solares
TM
Smart Spa Parts Manual
CD0039
42
Rev:1121
8
[res long drain]
Reservoir taking too long to
drain. Verify correct operation
of bottom reservoir float
sensor.
The bottom float does not reflect that tank has emptied
after a given amount of time. Could be sensor failure.
Manual Reset
[Prevents
reservoir pump
from running]
9
[UV Stuck On]
Light detected from UV lamps
after UV system deactivated.
Possible relay failure.
Light sensor indicate that UV lights didn’t turn off when
they should have. Could also be caused by relay getting
stuck in closed position (This is the case if UV lights are
truly on.) or by there being too much ambient light
behind the tub.
Auto Reset
10
[No Cold Supply]
Cold Supply Error
–
Can’t
bring down water temp.
Check cold supply and verify
pully secured to Rada shaft.
System unable to drop water temperature. Could be
caused by cold supply be turned off, loss in cold side
water pressure, or screw/ setscrew securing large pully to
Rada becoming loose. If large pully becomes loose it will
slip relative to brass shaft.
Auto/ Manual
Reset