Solares
TM
Smart Spa Parts Manual
CD0039
39
Rev:1121
Preventative Maintenance Schedule
Bathing System
Description
Mthly
3
Mos
6
Mos
1 Yr
Notes/ Comments
Inspect Water Supply
Lines
X
Inspect incoming lines from wall to Rada®
valve.
Cleaning &
Disinfecting System
X
Ensure Rinse, Clean, and Disinfect solenoids
all work correctly.
Fill & Shower
X
Ensure tub fill, shower wand, and reservoir fill
(if equipped) all open/ close correctly.
Shower Wand and
Hose
X
Test operation for proper flow and pressure
Carrier Docking Latch
X
Ensure latch is secured to frame and latch
locks when pushed in. Releases when release
button hit twice in quick succession.
Rails
X
Verify pockets and stops in rails are in good
shape and not excessively rounded. (Can hold
carrier securely.)
Thermostatic mixing
valve
X
Verify unit adjusts temperature correctly
when target temperature is changed.
Thermistor
X
Verify water temperature dispensed by tub fill
matches temperature shown on the screen.
Remedy Bulbs
X
X
Remove and clean annually if using Apollo
cleaning solutions, otherwise every six
months. Verify UV indicator lights and UV
bulbs are working. Average UV bulb life span
is approximately five years.
HMI
X
Verify system responds appropriately to
button presses.
Inspect Door Gasket
X
Verify gasket is free of tears and damage.
Ensure gasket is adhered securely to door.
Whirlpool plumbing &
pump/ motor.
X
Check for water leaks
Tub Drain valve
assembly.
X
Inspect for leaks; verify correct operation.
Tub Drain valve
assembly.
X
Grease slide valve.
Tub Tilt
X
Verify tub tilts all the way up and down
without issue. Ensure tub is stable and doesn’t
shift left to right.