Error and Notification Messages
www.3ware.com
249
Action
None required.
If errors persist, contact technical support at
http://www.3ware.com/support/
index.asp.
003A Drive power on reset detected
Event Type
Error
Cause
The controller has detected that a drive has lost power and then restarted. The
controller may degrade the unit if it is a redundant unit (non-redundant units
cannot be degraded).
Action
If this drive was the only one to lose power, check the cable connections.
Also, check that your power supply is adequate for the type and number of
devices attached to it.
See Also
For troubleshooting information and a link to drive manufacturer diagnostic
utilities, see
http://www.3ware.com/KB/article.aspx?id=14927.
003B Rebuild paused
Event Type
Information
Cause
The rebuild operation is paused.
Rebuilds are normally paused for two (formerly ten) minutes after a system
first boots up and during non-scheduled times when scheduling is enabled.
Disabling or modifying the schedule with 3DM or CLI will allow the rebuild
to resume.
See Also
“Scheduling Background Tasks” on page 156