Setting the Auto Rebuild Policy
www.3ware.com
85
To view controller polices in 3BM
You can also view and change these controller polices in 3BM, as shown in
Figure 40.
1
On the main 3BM screen,
Tab
to
Settings
and press
Enter
.
2
On the pop-up menu, select
Controller Policies
and press
Enter
.
The Policy Control screen displays.
Figure 40. 3BM Policy Control Screen
Setting the Auto Rebuild Policy
The Auto Rebuild policy determines how the controller firmware will attempt
to rebuild degraded units.
When Auto Rebuild is disabled, only spares will be automatically used to
rebuild degraded units. When Auto Rebuild is enabled, the firmware will
select drives to use for automatically rebuilding a degraded unit using the
following priority order.
•
Smallest usable spare.
•
Smallest usable unconfigured (available) drive.
•
Smallest usable failed drive.
Enabling Auto Rebuild allows you to add a drive to the controller and have it
be available for a rebuild, without having to specify it as a spare.
With Auto Rebuild enabled, if you accidentally disconnect a drive (causing
the controller to see it as a failed drive) and then reconnect it, the controller
will automatically try to use it again.
You can enable or disable the Auto-Rebuild policy through 3DM or 3BM.