Error and Notification Messages
www.3ware.com
227
Error and Notification Message Details
0001 Controller reset occurred
Event Type
Information
Cause
The device driver has sent a soft reset to the 3ware RAID controller. The
driver does this when the controller has not responded to a command within
the allowed time limit (30 sec.). After the soft reset command has been sent,
the driver will resend the command.
Action
If this message occurs more than three times a day, collect the system logs and
contact Technical Support.
If this message is seen while installing a 9550SX controller card under
FreeBSD, it is due to the APIC (Advanced Programmable Interrupt
Controller) being enabled. To complete the installation you must disable
APIC. See Knowledge Base 14853:
http://www.3ware.com/kb/
article.aspx?id=14853.
0058 Battery capacity is below warning level
0059 Battery capacity is below error level
005A Battery is present
005B Battery is not present
005C Battery is weak
005D Battery health check failed
005E Cache synchronization completed
005F Cache synchronization failed; some data lost
Table 13: Error and Notification Message List
Value Message