Cura
Cura Tab – Print – Extrusion – Distance Retraction Option:
High Retraction Speed: It could cause bubbles inside nozzle. A regular parameter
would be 40-50mm/sec, keeping in mind that it changes depending on the
material’s hardness you are using. To do so, you will have to go back to the
previous tabs and modify the value on
Speed (Slic3R)
and on
Retraction Speed
(CuraEngine).
High Filament Temperature: If the temperature configuration is not set correctly
and it is too high, the filament becomes very fluid and extrudes without request.
This can be changed in the filament temperature configuration and it can be
done while is printing, as previously explained.
The filament manufacturer will establish the ideal temperature range for the
extrusion.
Summary of Contents for ILC