1-5
Table 1-4
Enable the specified port to process flush messages received from the specified control
VLAN
Operation
Command
Remarks
Enter system view
system-view
—
System
view
smart-link flush enable control-vlan
vlan-id port interface-type interface-number
[
to interface-type interface-number
]
interface interface-type interface-number
Enable the
specified port(s)
to process flush
messages
received from
the control
VLAN
Ethernet
port view
smart-link flush enable
control-vlan
vlan-id
Required, use
either approach.
By default, no
control VLAN for
receiving flush
messages is
specified.
Precautions
When configuring Smart Link, pay attention to the following points:
1) A port or a link aggregation group cannot serve as a member port for two Smart Link groups. On
the other hand, a port or a link aggregation group cannot serve as a member for a Smart Link group
and a Monitor Link group at the same time.
2) STP cannot be enabled on the member ports of a Smart Link group. An STP-enabled port or a link
aggregation group with an STP-enabled port cannot serve as a member port for a Smart Link
group.
3) A Smart Link/Monitor Link group with members cannot be deleted.
4) Smart Link/Monitor Link is mutually exclusive with remote port mirroring.
5) When a Combo port operates as a member port of a Smart Link group, the optical port and the
electrical port of the Combo port must not be both engaged with a cable at the same time.
6) When you copy a port, the Smart Link/Monitor Link group member information configured on the
port will not be copied to other ports.
7) If a single port is specified as a member of a Smart Link/Monitor Link group, you cannot execute the
lacp enable
command on this port or add this port into other dynamic link aggregation groups,
because these operations will make this port become a link aggregation group member.
8) If no control VLAN is configured for flush message processing, the device will forward received
flush messages without processing them.
9) If the control VLAN for receiving flush messages configured on an associated device is different
than the one for sending flush messages configured on the corresponding Smart Link device, the
device will forward received flush messages without processing them.
10) In the static or manual link aggregation group which serves as a Smart Link group member, if a
member port can process flush messages, this function cannot be synchronized to the other ports
in the aggregation group automatically, that is, the other member ports in the aggregation group
cannot process flush messages. The function of processing flush messages must be manually
configured for each port in the aggregation group.
11) The VLAN configured as a control VLAN to send and receive flush messages must exist. You
cannot directly remove the control VLAN. When a dynamic VLAN is configured as the control VLAN
for the Smart Link group, this VLAN will become a static VLAN, and the prompt information is
displayed.