2.5.7 Connecting to a heating system = AUX2 - 12-24V
12 - 24 V contact
All types of auxiliary
device
12 - 24 V
Heating system
with remote on/off control
1. use an appropriate length of a 2 x 0.75 mm²
cable (not supplied).
2. Use this cable to connect the appliance contact
(AUX2) to the remote on/off control of the
heating system (see connection details in the
associated installation manual).
3. Turn the heating system on. Set the
temperature setpoint of the heating system to
its maximum (and set to the desired mode if
there are several heating modes are available).
The chlorinator will use the water temperature
measured by its sensor to manage the activation
of the heating system according to the
temperature setpoint.
1 2
AUX 2 (12-24 V)
A = Chlorinator
B = Heating system
A
Connection of a heating system
with remote on/off control
2 x 0.75 mm
Heating system
without remote on/off control
1. use an appropriate length of a 2 x 0.75 mm² cable
(not supplied).
2. Disconnect one of the 2 flow switch (D) wires from
the terminal block of the heating system (B) (refer to
the manual if necessary).
3. Connect the wire from terminal 1 of the
chlorinator (A) in place of the flow switch (D) wire
that was disconnected from the terminal block of
the heating system (B).
4. Connect the disconnected flow switch wire (step
2) with the wire from terminal 2 of the chlorinator
(A) using a suitable connection terminal (C).
5. Turn the heating system on. Set the temperature
setpoint of the heating system to its maximum
(and set to the desired mode if there are several
heating modes are available). The chlorinator will
use the water temperature measured by its sensor
to manage the activation of the heating system
according to the temperature setpoint.
1 2
AUX 2 (12-24 V)
A = Chlorinator
B = Heating
system
C = Connection
terminal block
D = Flow switch
A
Connection of a heating system
without remote on/off control
2 x 0.75 mm