12
2.5.2 Identifying the functions to be connected
Terminal
block
messages
Type
Cable
clamp
Functions
Hydroxinator ® iQ
With pH Link or Dual
Link
SENS
Input
-
Connection for the control board
for pH Link and Dual Link modules
/
PUMP
Input
-
Connection for the pH regulation pump
for pH Link and Dual Link modules
/
CELL
Output
1
Connection for the electrolytic cell
UI
Output
-
Connection for the display
TEMP
Input
3
Conenction for the temperature sensor
Flow
Input
2
Connection for the flow switch
iAL RS485
Input
4
Function not used – do not wire
/
/
VSP RS485 Output
5
Connection dedicated to controlling the
Zodiac® variable-speed filter pump
/
-
Function not used – do not wire
/
/
COVER
Input
7
Connection for the roller shutter/cover for
automatically managing the LOW function
SLAVE
Input
8
Connection for an external appliance for the
ON/OFF control of chlorinator (automatic
regulation, etc.)
/
AUX 2 12-
24V
Output
9
Connection dedicated to the ON/OFF control
of a
low-voltage
device. Connection used to
control a heating system. This connection
does not power the device: it manages the
ON/OFF function.
AUX 1 230 V Output
10
Connection dedicated to the ON/OFF control
of a
high-voltage
device. This connection
does not power the device: it manages the
ON/OFF function.
PUMP 230V Output
11
Connection dedicated to the power supply to
the pool filter pump.
MAINS
Input
12
Mains power supply to the appliance
110-240 VAC - 50/60 Hz
: Connections made during manufacture
: Mandatory connections to be made
: Function to be connected
(optional)