38
Heating priority (optional):
The "heating priority" function is only displayed if a heating system and a filter pump (single- or variable-speed pump)
have been declared in the chlorinator.
• Press
. Browse the menu using the
buttons.
Press
to confirm.
•
Select the speed of the pump in "heating priority" mode (if a compatible Zodiac® variable-speed pump
has been declared).
Use a speed that is less than or equal to the speed normally used for filtration timers
:
- If a filter pump has been declared and the heating priority is activated outside of the filtration timers:
filtration will occur for 5 minutes every 120 minutes in order to measure the water temperature.
- If necessary, the filter pump and the heating system will be activated until the desired water temperature
setpoint is reached.