7
1.2 I Technical specifications
1.2.1 Chlorinator
Hydroxinator®
iQ 10
Hydroxinator®
iQ 18
Hydroxinator®
iQ 22
Hydroxinator®
iQ 35
Nominal chlorine production
10 g/h
18 g/h
22 g/h
35 g/h
Nominal output current
2.8 A
3.6 A
5 A
7.2 A
Recommended mineral level -
minimum mineral level
4 g/L - 3.3 g/L min.
Power supply voltage
110 - 240V
50-60 Hz
Electrical power
200 W maximum
Protection rating
IP43
Cell throughput (minimum/
maximum)
5m³/h < 18m³/h
Maximum allowable pressure in
the cell
2.75 bar
Operating water temperature
5°C < 40°C
Frequency bands
2.400 GHz - 2.497 GHz
Radio output power
+19.5 dBm
1.2.2 Optional pH Link or Dual Link module
pH Link
Dual Link
Supply voltage
Extra-low voltage (connected to the control box)
Peristaltic pump flow rate
1.2 L/h
Maximum back pressure (injection)
1.5 bar
pH and ORP sensor type
Combined (pH=blue/ORP=yellow)
pH correction
pH minus only (hydrochloric acid or sulphuric acid)
pH minus dispensing
Proportional cyclic
pH sensor calibration
1 point or 2 points (pH 4 and pH 7)
ORP sensor tolerances
/
10 ppm maximum
(shock chlorination)
ORP sensor calibration
1 point (470 mV)
Sensor cable length
3 metres
EN