42
5.3.2 Configuring the pH setpoint
Current sensor measurements
Setpoints
The pH setpoint configuration determines the time when acid is added to the system to reduce the water's pH.
The
default value of the pH setpoint is 7.2.
To determine the value of the setpoint to be configured, refer to Taylor's balance, see
“4.2.3 Weekly analyses”.
• Press
and
browse the menu using the
buttons.
Press
to confirm.
•
Select the desired setpoint value (from 6.8 to 7.6):
Principle of injecting pH into the appliance:
Example of 4 cycles with a setpoint at 7.4 pH and acid regulation (standard alkalinity):
• pH ≥ 7.55
: 20% injection (2 min) & 80% pause (8 min)
• pH ≥ 7.7
: 50% injection (5 min) & 50 % pause (5 min)
• pH ≥ 7.85
: 75% injection (7 min 30 sec) & 25% pause (2 min 30 sec)
• pH > 7.9
: 100% injection (10 min)
Changes in the pool's pH
Dispensing
cycle times
pH setpoint - 7.4