2.5.3 Electrical connection steps
•
Identify the functions to be connected and locate the position of the cable clamp,
see “2.5.2 Identifying
the functions to be connected”.
•
Check that the cables used comply with the intended use and with the regulations in force.
•
Identify the input for each desired function at the bottom of the control box:
pH = blue
ORP = yellow
View from below of a control box with an installed module
•
Pass the cable into the associated cable gland or pierce a hole in the PVC diaphragm (made of rubber) using
a screwdriver of an appropriate diameter.
•
Identify the terminal block dedicated to the desired function using the identification zones:
Low-voltage
part
High-voltage
part
•
Install a cable clamp (supplied) to mechanically hold the cable against the appliance's frame; the position
of the cable clamp is shown,
see “2.5.2 Identifying the functions to be connected”.
•
If the filter pump (single- or variable-speed pump) is connected to the chlorinator, it must be grounded
using the dedicated grounding stud by crimping an appropriately-sized lug for the wire (not supplied).