44
5.3.4 Configuring the ORP setpoint
The ORP setpoint configuration determines the time at which chlorine is produced by the appliance. The level of free
chlorine must be controlled at regular intervals after initial installation.
The default value of the ORP setpoint is 700 mV.
The value of the setpoint depends on the pool's environment, its affluence, and the amount of stabiliser present in the
pool water, etc.
• Press
and browse the menu using the
buttons. Press
to
confirm.
•
Select the desired setpoint value (from 600 mV to 900 mV) using the
buttons.
• Press
to confirm.
(ORP = Oxidation Reduction Potential)
5.3.5 Activating the pH pump
To prevent exposure to acid during installation, the dispenser pump is deactivated for the first 8 hours of operation;
during these first 8 hours, the pH value is measured and displayed as "- - - -".
• Hydrochloric acid is a hazardous chemical that may cause burns, lesions and irritations.
Handle with care and use protective equipment (gloves, safety glasses, overalls). Refer to the
product's MSDS for more information.
• Always pour the acid into the water.
• Once cleaning is complete, dispose of the solution according to the standard in force in the
country of use.
•
The pH pump can be manually activated during this 8-hour period; press
and
browse the menu
using the
buttons.
Press
to
confirm.
• Press
to exit.