3.5.2 Installing the pH minus suction line
•
Cut a suitable length of hose from the coil supplied to connect the container of pH minus to the peristaltic
pump.
•
Unscrew the connector cap
and attach the hose to the connector at the outlet of the peristaltic pump,
see
figure .
Screw the cap in place.
•
Reposition the protective cover on the peristaltic pump.
•
Drill two holes into the cap of the pH minus container,
see figure
:
-
One hole suited to the diameter of the hose to aspirate the product.
-
One smaller hole to prevent the container from becoming deformed during aspiration of the product.
•
Pass the free end of the hose through the hole made in the cap and put the ceramic weight provided and
the support tip on the hose,
see figure
.
•
Ensure that ALL connections are correct and watertight before operating the appliance.
Do not place the pH minus container directly beneath electrical equipment in the technical room to prevent
risk of corrosion resulting from potential acidic vapours.