Programming
84
♦
To receive the configuration from a console
1. Use the supplied programming cable to connect your PC with the console:
• If you have a cable with one RJ connector (P/N 709-7266 or 709-7400), use it
to connect the serial port of your computer to the COMB jack (combined data)
on the console.
• If you have a cable with two RJ connectors (P/N 709-7084 or 709-7417), use it
to connect the serial port of your computer to the DATA IN and DATA OUT
jacks on the console (these jacks might also be named LOOP IN and LOOP
OUT). The cable ends are labeled for specific ports (IN vs OUT) and must be
connected correctly.
If there are existing cables already connected to any of these ports, you must
temporarily remove them while programming. Before removing these existing
cables, ensure they are labeled so they can be returned to the proper ports.
2. There is an unlabeled switch on the bottom of the Model 4010 used to switch the
console between RUN and PROGRAM modes. Move the switch to the program
position, which is towards the gooseneck MIC and away from the DATA IN,
DATA OUT, and COMB jacks.
The console display shows “PROGRAM”.
3. In CPSW, click
Communication, Receive config from Position
.
4. Click
OK
to begin receiving the configuration.
The console display shows “UpLoading CPS” while it is sending data and shows
“DONE” when all data is transferred.
If you receive the error message “Console did not send any data”, check the
following items and try again:
• Check your cable for loose or incorrect connections
• Ensure the RUN/PROGRAM switch is set to PROGRAM
• Check your serial port settings (see
♦
To load a configuration from a file
1. Click
File, Open
.
Note
The USB-to-serial port adapter provided by Zetron (P/N 802-0516)
is tested and the recommended adapter for this application. Many
third party USB-to-serial port adapters are inconsistent with their
serial port implementation and do not reliably communicate with
Zetron equipment.