25
Configuring Dispatch Consoles
Model 4010 Options
The Model 4010 console may be shipped with optional features that deviate from standard
operation. There is a method to determine what options are enabled in a particular console.
The Model 4010 has a programming switch located on the bottom of the console. Put the
programming switch in the program position* for approximately one second and then
return it to the normal run position while pressing the # key on the keypad. As long as the
# key is held down the option code may be read from the LCD display.
If no options are installed in the unit then the display will show “Opt:-”. If there are
options enabled in the unit then “Opt:” will be followed by one or more letters indicating
the options enabled. Use
to interpret the letters appearing after the prompt.
Table 3: Model 4010 Console Option Code Definition
Note
, the asterisk (*) is used to show the typical position of a
jumper. However, the M4010 is configured and programmed at the
factory according to various customer preferences, so your default
positions from the factory may be different than the typical
positions listed here.
Note
* On the Model 4010, the “program” position is toward the Select
speaker.
Option
Code
Description
Default
B
DC I Boost enabled. For DC channels only, this
provides an initially boosted current to overcome
greater capacitance found in longer wire runs. After
the initial boost, current returns to normal levels.
DC I Boost disabled. Normal current levels
are used.
D
D-PTT always selects the desk mic. This option is
required when using both a desk mic and a
gooseneck mic at the same time.
A contact closure on D-PTT selects the
dynamic input programmed by CPSW.
C
Coded/Clear TX feature enabled. For tone control
only, this allows encrypted control of the base
station.
Coded/Clear TX feature disabled.
X
Extended Paging enabled. This adds several paging
formats: Rotary Dial/1500 Hz or 2805 Hz, Plectron,
Quick-Call I (2+2), and 5/6 Tone Sequential.
Paging formats are limited to Motorola Two-
Tone, GE Two-Tone, DTMF, and alert tones.
I
Instant Call Paging enabled. This allows frequently
used pages or sequences of pages to be initiated and
automatically steered to the correct channel with a
single key press.
Instant Call Paging disabled. All pages are
entered manually.
If an option code is not displayed, that option is set to the default condition.