41
Preliminary System Check
Preliminary System Check
After the system has been completely wired and configured, it is time to turn on the power
to the system. This section of the manual suggests the sequence to follow when initially
bringing the system on-line. This sequence will help identify any console operational
problems that may have occurred.
Bringing the System On Line
1. Turn on the power to the Console by plugging it in. If the console display remains
blank when the power is turned on, check the power supply voltage and polarity. In
addition, check the fuse F1 inside the Dispatch Console.
2. Check the console system configuration, which is displayed when the Model 4010
is powered up (or when it is switched out of program mode).
The display shows the configuration file name in the upper left corner, the detected
card status in the lower line, and the operating software version in the lower right
corner.
The detected card status is displayed in the following format:
TaDbXcPeNi
Where a = the number of tone/local channels found
b = the number of DC channels found
c = the number of Aux. I/O channels found
e = the number of phone channels found
i = the number of ANI channels found
The card status display represents the actual physical cards detected by the
firmware and not necessarily the configuration programmed by CPSW (although
they should agree for proper console operation).
If the display shows PROGRAM instead of the console system configuration, then
the Dispatch Console has the programming switch located on the bottom of the
unit in the wrong position. Place the switch toward the DATA IN connector on the
side of the unit. The display should now show the console system configuration.
If the display shows CPS DATA ERR, the configuration stored in the console does
not contain the proper information and must be reloaded. Refer to
on page 83 for the proper procedure.
3. Change the display to show the time, date, and “Model 4010” by pressing the
Diagnostic Reset key. If that key is not programmed, press any other key. The
clock has been set at the factory for the Pacific Time Zone. The clock set function
can be used to change the time if required. Refer to the
Model 4010 Radio
Dispatch Console Operator’s Manual
(P/N 025-9226) for this procedure.
Содержание 4010
Страница 1: ...Model 4010 Radio Dispatch Console Installation and Programming 025 9227S ...
Страница 46: ...Console Installation 46 025 9227S ...
Страница 78: ...Option Installation 78 025 9227S ...
Страница 134: ...Appendix D Troubleshooting 134 025 9227S ...