Operation
ZeroClamp zero point clamping system
– manual
28
7. Operation
Caution!
The zero point clamping system may fill up with liquids (lubricoolant)
in clamped or non-clamped condition, if it is not used for a longer
period of time. As a result, the clamping force may not be exerted or
the zero point clamping system does not fully open during its first
subsequent use.
During the processing the clamping pot must be covered by the
pallet, workpiece or of the fixture.
Make sure that the zero point clamping system cannot fill up with
liquid when it is not used!
Release the zero point clamping system of liquids on a weekly basis!
Caution!
The clamping sheets in the zero point clamping system may
adhere in clamped and non-clamped condition, if the zero point
clamping system is not in use for a longer period of time. As a
result, the clamping force cannot be exerted or the zero point
clamping system does not fully opened when used again for the
first time.
Spray the exposed mechanical parts in the chuck once or twice a
week using fine oil (approved agents see 8.4 Cleaning) while
operating the clamping in order to spread the oil. This way the
mechanical parts are kept movable and smooth.
Caution!
When operating the zero point clamping systems the skin of your
fingers can get caught between the clamping elements.
Do not reach inside the clamp bolt support!
Caution!
Unused clamping pots shall be fitted with a locking bolt. Specially
designed clamps with a media transfer are tob e protected with a
sealing plate against contamination.
Caution!
Perform a complete functional test including all special functions
before operating the zero point clamping system.