5.2.4 Connection of an encoder
ACE0/COMBIAC0 can handle different types of encoder. To control AC
motor, it is necessary to install an incremental encoder with 2 phases shifted
by 90°. The encoder supply can be 5 V or 12 V. For special applications it is
possible to install incremental encoder with zero-position signal.
A25
+5V/+12V
Positive power supply.
A5
GND
Negative
power
supply.
A14
ENC A
Phase A.
A13
ENC B
Phase B.
A20
Z POS
Z-index.
Connection of a standard encoder.
Connection of an encoder with zero-position signal.
U
VERY IMPORTANT
It is necessary to specify in the commercial order the type of encoder used,
in terms of power supply and electronic output, so that the logic can be
properly set by Zapi lines.
U
VERY IMPORTANT
The number of pulses/rev can be properly set using the dedicated
parameters (see paragraph 8.2.5).
U
The maximum speed detectable by standard hardware configuration can be
limited depending on number of pulse/rev. Contact Zapi technician for
checking this aspect.
U
VERY IMPORTANT
It is strongly suggested, for safety reasons, to lift the wheels from the floor
and set the correct value according to the type of sensor used prior to
perform any operation with the truck.
Содержание ACE0 2mC
Страница 13: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 13 155 3 2 Connection drawings 3 2 1 AC Traction configuration...
Страница 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Страница 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Страница 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Страница 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Страница 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...