AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
Page – 33/155
potentiometers is available on pin
A8
in substitution of EV5 output.
Output voltage is configurable via hardware by internal jumper to +12V or +5V;
maximum output current is 100 mA.
4
Actual values for “+12V” and “+5V” are respectively 13.1 V ± 0.5 V and
5 V ± 0.3 V.
Protection
Analog supply output is protected against over current with a thermal shut down
and protected against accidental connection to +B with a diode.
Connector position
GND
A5
, PPOT (+5/+12)
A8
.
4.4.13 CAN bus
CAN bus interface is available for communication with the controller, featuring:
Physical Interface according to ISO 11898-2.
Data rate can be 125, 250 or 500 kbit/s.
CAN driver is +5 V supplied and provides a rail to rail signal on the
differential output (CANH - CANL).
An
internal
120
Ω
termination resistor can be built-in.
Common-mode filter (resistors and capacitor) is present.
Protection
CAN bus interface is protected against accidental connection to +B and -B and
ESD protected.
Connector position
CANL
A27
, CANH
A28
.
4
CAN-cabling shall use a pair of twisted wires for CANH and CANL wires.
The CAN wiring shall have a characteristic impedance of 120
Ω
and both
physical ends of the CAN bus shall be terminated with 120
Ω
between CANH and
CANL for best possible noise immunity.
Содержание ACE0 2mC
Страница 13: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 13 155 3 2 Connection drawings 3 2 1 AC Traction configuration...
Страница 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Страница 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Страница 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Страница 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Страница 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...