Page – 138/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
12 PERIODIC MAINTENANCE
Check the wear and the condition of the contactors’ moving and fixed contacts.
Electrical contacts should be checked every
3 months
.
Check the Foot pedal or Tiller microswitch. Using a suitable test meter, confirm
that there is no electrical resistance between the contacts by measuring the
voltage drop between the terminals. Switches should operate with a clear click
sound.
Microswitches should be checked every
3 months
.
Check the Battery cables, cables connected to the inverter, and cables
connected to the motor. Ensure that the insulation is sound and that the
connections are tight.
Cables should be checked every
3 months
.
Check the mechanical functionality of the pedals or tiller. Control that the return
springs are ok and that the potentiometers excursion matches their full or
programmed level.
Check every
3 months
.
Check the mechanical functionality of the Contactor(s). Moving contacts should
be free to move without restriction.
Check every
3 months
.
Checks should be carried out by qualified personnel and any replacement parts
used should be original. Beware of NON ORIGINAL PARTS.
The installation of this electronic controller should be made according to the
diagrams included in this Manual. Any variations or special modifications should
be evaluated with a Zapi Agent. The supplier is not responsible for any problem
that arises from connections that differ from information included in this Manual.
During periodic checks, if a technician finds any situation that could cause
damage or compromise safety, the matter should be brought to the attention of a
Zapi Agent immediately. The Agent will then take the decision regarding the
operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.
U
IMPORTANT NOTE ABOUT WASTE MANAGEMENT:
This controller has both mechanical parts and high-density electronic parts
(printed circuit boards and integrated circuits). If not properly handled
during waste processing, this material may become a relevant source of
pollution. The disposal and recycling of this controller has to follow the
local laws for these kinds of waste materials.
Zapi commits itself to update its technology in order to reduce the
presence of polluting substances in its products.
Содержание ACE0 2mC
Страница 13: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 13 155 3 2 Connection drawings 3 2 1 AC Traction configuration...
Страница 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Страница 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Страница 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Страница 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Страница 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...