Page – 18/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
4 I/O INTERFACE DESCRIPTION
4.1 Power
connectors
Power connections are on vertical posts where to bolt power-cables lugs. On the
cover of the converter they are labeled as:
Terminal name
Description
+B
Positive battery termination
-B
Negative battery termination
U, V, W
Motor phase terminations.
-P
Negative terminal of pump DC motor (COMBIAC0 only).
In combination with COMBIAC0, DC pump motor must be connected between
terB and -P. PWM frequency at -P is 16 kHz. Terminal -P is protected by
short circuit detection, voltage and current measurements. Freewheeling diodes
to +B are built in (MOSFETs internal diodes).
4.2 Ampseal
connector
Inverter is equipped with a 35-poles Ampseal connector like that of the figure.
Each of the 35 pins is referred to as “
A#
”, where “A” denotes the connector name
and “#” the pin number, from 1 to 35.
35-poles Ampseal connector.
The following table lists the functional associations for the pins of the 35-poles
Ampseal connector.
4
For each I/O pin, the default Zapi function is indicated. The function of each pin
can be changed in customized software.
4
Some I/O pins can have special functionalities depending on the controller
configuration.
Содержание ACE0 2mC
Страница 13: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 13 155 3 2 Connection drawings 3 2 1 AC Traction configuration...
Страница 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Страница 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Страница 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Страница 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Страница 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...