Page – 10/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
2.4 Voltage
ratings
Nominal DC voltage
24V
36/48V
80V
Conventional working voltage range
19.2 V ÷ 28.8 V
28.8 V ÷ 57.6 V
57.8 V ÷ 96 V
Non-operational overvoltage limits
35V
65V
115V
Non-operational undervoltage limits
10V
10V
30V
4
Conventionally, the controller can be set to operate without alarm in the range
from 80% to 120% of the nominal battery voltage. With a different DC voltage
than specified, the controller raises an alarm.
4
Undervoltage and overvoltage thresholds are defined by hardware. After start-up,
controller is fully operative if the supply voltage stays within these limits.
4
Undervoltage is evaluated on the KEY input (
A10
); overvoltage is evaluated on
the positive battery teB.
Содержание ACE0 2mC
Страница 13: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 13 155 3 2 Connection drawings 3 2 1 AC Traction configuration...
Страница 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Страница 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Страница 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Страница 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Страница 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...