Page – 110/155
AF6ZP0CA – COMBIAC0 & ACE0 2uC – User Manual
current from the capacitors-charging circuit, thus preventing the caps
from charging well. Check if a lamp or a dc/dc converter or an auxiliary
load is placed in parallel to the capacitor bank.
-
The charging resistance or PTC may be broken. Insert a power
resistance across line-contactor power terminals; if the alarm disappears,
it means that the charging resistance is damaged.
-
The charging circuit has a failure or there is a problem in the power
section. Replace the controller.
CHECK UP NEEDED
(MDI/LED code = 0)
Cause:
This is a warning to point out that it is time for the programmed maintenance.
Troubleshooting:
Turn on the CHECK UP DONE option after that the maintenance service.
COIL SHOR. EB
(MDI/LED code = 76)
Cause
This alarm occurs when an overload of the EB driver (output NEB
A4
)
occurs.
Troubleshooting
-
Check the connections between the controller outputs and the loads.
-
Collect information about characteristics of the coil connected to the
driver and ask for assistance to a Zapi technician in order to verify that
the maximum current that can be supplied by the hardware is not
exceeded.
-
In case no failures/problems have been found, the problem is in the
controller, which has to be replaced.
COIL SHOR. EVAUX
(MDI/LED code = 21)
Cause:
This alarm occurs when an overload of the EV drivers occurs.
Troubleshooting:
-
Check the connections between the controller outputs and the loads.
-
Collect information about characteristics of the coils connected to the
drivers and ask for assistance to a Zapi technician in order to verify that
the maximum current that can be supplied by the hardware is not
exceeded.
In case no failures/problems have been found, the problem is in the
controller, which has to be replaced.
COIL SHOR. MC
(MDI/LED code = 76)
Cause
This alarm occurs when an overload of the MC driver (output NMC
A12
)
occurs.
Troubleshooting
-
Check the connections between the controller outputs and the loads.
-
Collect information about characteristics of the coil connected to the
driver and ask for assistance to a Zapi technician in order to verify that
the maximum current that can be supplied by the hardware is not
exceeded.
Содержание ACE0 2mC
Страница 13: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 13 155 3 2 Connection drawings 3 2 1 AC Traction configuration...
Страница 14: ...Page 14 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 2 AC Pump configuration...
Страница 15: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 15 155 3 2 3 AC CAN Open configuration...
Страница 16: ...Page 16 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual 3 2 4 PMSM Traction configuration...
Страница 17: ...AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Page 17 155 3 2 5 PMSM Pump configuration...
Страница 98: ...Page 98 155 AF6ZP0CA COMBIAC0 ACE0 2uC User Manual Torque curves...