FORM 201.10-NM4
101
YORK INTERNATIONAL
SYSTEM 2 DATA
COMPRESSOR STATUS
OFF
RUN TIME
0 0 0 0 D-H-M-S
AVERAGE MTR = 0
0 %FLA
PHASE L1 MTR = 0
0 %FLA
PHASE L2 MTR = 0
0 %FLA
PHASE L3 MTR = 0
0 %FLA
DIFF OIL PRESSURE
0.0 PSID
SUCTION PRESSURE
76.0 PSIG
SATURATED SUCTION
44.9 DEGF
SUCTION TEMP
45.2 DEGF
SUPERHEAT
0.3 DEGF
DISCHARGE PRESSURE
114.0 PSIG
SATURATED DISCHARGE
64.8 DEGF
DISCHARGE TEMP
66.4 DEGF
OIL TEMP
101.4 DEGF
LIQUID INJECTION VALVE
OFF
FORWARD FANS
OFF
REVERSE FANS
OFF
LIQUID LINE SOLENOID
OFF
RUN PERMISSIVE
ON
SYSTEM 3 DATA
COMPRESSOR STATUS
ON
RUN TIME
0 1 2 24 D-H-M-S
AVERAGE MTR = 103
55 %FLA
PHASE L1 MTR = 105
56 %FLA
PHASE L2 MTR = 97
52 %FLA
PHASE L3 MTR = 109
58 %FLA
DIFF OIL PRESSURE
2.9 PSID
SUCTION PRESSURE
60.8 PSIG
SATURATED SUCTION
34.0 DEGF
SUCTION TEMP
43.3 DEGF
SUPERHEAT
8.7 DEGF
DISCHARGE PRESSURE
230.5 PSIG
SATURATED DISCHARGE
109.9 DEGF
DISCHARGE TEMP
138.0 DEGF
OIL TEMP
126.7 DEGF
LIQUID INJECTION VALVE
OFF
FORWARD FANS
2
REVERSE FANS
OFF
LIQUID LINE SOLENOID
ON
RUN PERMISSIVE
ON
YORK INTERNATIONAL CORPORATION
MILLENNIUM SCREW CHILLER
ISN OPTION ENABLED
SOFTWARE VERSION C.A12.03.01
SAFETY SHUTDOWN NUMBER 2
SHUTDOWN @ 9:25AM 6/3/98
SYS 1 HIGH OIL TEMP SHUTDOWN
SYS 2 STATUS: NO FAULTS
SYS 3 STATUS: NO FAULTS
RETURN WATER TEMP
47.0 DEGF
LEAVING WATER TEMP
44.5 DEGF
LOW WATER CUTOUT
36.0 DEGF
COOLING RANGE
41.0 TO 44.6 DEGF
TARGET TEMP
42.8 DEGF
AMBIENT AIR TEMP
50.0 DEGF
LOW AMBIENT CUTOUT
25.0 DEGF
LOW PRESSURE CUTOUT
44.0 PSIG
LEAD SYSTEM
SYS 1
LOCAL REMOTE SETTING:
LOCAL
SYSTEM 1 DATA
COMPRESSOR STATUS
ON
RUN TIME
0- 0- 22- 3 D-H-M-S
AVERAGE MTR = 107
57 %FLA
PHASE L1 MTR = 109
58 %FLA
PHASE L2 MTR = 101
54 %FLA
PHASE L3 MTR = 112
60 %FLA
DIFF OIL PRESSURE
1.6 PSID
SUCTION PRESSURE
61.3
PSIG
SATURATED SUCTION
35.1 DEGF
SUCTION TEMP
55.0 DEGF
SUPERHEAT
19.9 DEGF
DISCHARGE PRESSURE
221.8
PSIG
SATURATED DISCHARGE
107.5 DEGF
DISCHARGE TEMP
229.2 DEGF
OIL TEMP
228.0 DEGF
LIQUID INJECTION VALVE
ON
FORWARD FANS
2
REVERSE FANS
OFF
LIQUID LINE SOLENOID
ON
RUN PERMISSIVE
ON
SYSTEM 2 DATA
COMPRESSOR STATUS
OFF
RUN TIME
0 0 0 0 D-H-M-S
AVERAGE MTR = 0
0 %FLA
PHASE L1 MTR = 0
0 %FLA
PHASE L2 MTR = 0
0 %FLA
PHASE L3 MTR = 0
0 %FLA
DIFF OIL PRESSURE
0.0
PSID
SUCTION PRESSURE
62.2
PSIG
SATURATED SUCTION
35.2 DEGF
SUCTION TEMP
37.0 DEGF
SUPERHEAT
1.8 DEGF
DISCHARGE PRESSURE
92.8
PSIG
SATURATED DISCHARGE
55.1 DEGF
DISCHARGE TEMP
56.0 DEGF
OIL TEMP
180.4 DEGF
LIQUID INJECTION VALVE
OFF
FORWARD FANS
OFF
REVERSE FANS
OFF
LIQUID LINE SOLENOID
OFF
RUN PERMISSIVE
ON
SYSTEM 3 DATA
COMPRESSOR STATUS
ON
RUN TIME
0 0 0 0 D-H-M-S
AVERAGE MTR = 93
47 %FLA
PHASE L1 MTR = 93
47 %FLA
PHASE L2 MTR = 93
48 %FLA
PHASE L3 MTR = 93
46 %FLA
DIFF OIL PRESSURE
2.9
PSID
SUCTION PRESSURE
60.8
PSIG
SATURATED SUCTION
34.9 DEGF
SUCTION TEMP
54.0 DEGF
SUPERHEAT
19.1 DEGF
DISCHARGE PRESSURE
210.5
PSIG
SATURATED DISCHARGE
104.8 DEGF
DISCHARGE TEMP
125.9 DEGF
OIL TEMP
122.3 DEGF
LIQUID INJECTION VALVE
OFF
FORWARD FANS
2
REVERSE FANS
OFF
LIQUID LINE SOLENOID
ON
RUN PERMISSIVE
ON
YORK INTERNATIONAL CORPORATION
MILLENNIUM SCREW CHILLER
ISN OPTION ENABLED
SOFTWARE VERSION C.A12.03.01
SAFETY SHUTDOWN NUMBER 3
SHUTDOWN @ 3:33PM 01 OCT 96
SYS 1 HIGH DSCH TEMP SHUTDOWN
SYS 2 STATUS: NO FAULTS
SYS 3 STATUS: NO FAULTS
RETURN WATER TEMP
49.6 DEGF
LEAVING WATER TEMP
44.7 DEGF
LOW WATER CUTOUT
36.0 DEGF
COOLING RANGE
41.0 TO 44.6 DEGF
TARGET TEMP
42.8 DEGF