3-52
IM 701450-51E
SPOLarity
<Space>
RISE
FALL
?
?
?
TYPE
<Space>
SPIBus
?
SSENable
<Space>
HIGH
LOW
?
:TRIGger:SPI:COMBination
Function
Sets the combination trigger or queries the
current setting.
Syntax
:TRIGger:SPI:COMBination
{ONLY|ONPattern|APATtern}
:TRIGger:SPI:COMBination?
Example
:TRIGGER:SPI:COMBINATION ONLY
:TRIGGER:SPI:COMBINATION? ->
:TRIGGER:SPI:COMBINATION ONLY
Description
Setting and Query are possible only on the
DL7480.
The command can be used only to set “ONLY”
on the DL7440.
:TRIGger:SPI:PATTern?
Function
Queries all settings related the pattern setting of
the combination trigger.
Syntax
:TRIGger:SPI:PATTern?
Example
:TRIGGER:SPI:PATTERN? ->
:TRIGGER:SPI:PATTERN:CLOCK NONE;
CHANNEL5 DONTCARE;
CHANNEL6 DONTCARE;
CHANNEL7 DONTCARE;
CHANNEL8 DONTCARE;CONDITION ENTER
Description
Setting and Query are possible only on the
DL7480.
:TRIGger:SPI:PATTern:CHANnel<x>
Function
Sets the condition (pattern or slope) of each
channel of the combination trigger or queries
the current setting.
Syntax
:TRIGger:SPI:PATTern:CHANnel<x>
{HIGH|LOW|DONTCARE|RISE|FALL}
:TRIGger:SPI:PATTern:CHANnel<x>?
<x>=5 to 8
Example
:TRIGGER:SPI:PATTERN:CHANEL5 HIGH
:TRIGGER:SPI:PATTERN:CHANEL5? ->
:TRIGGER:SPI:PATTERN:CHANEL5 HIGH
Description
Setting and Query are possible only on the
DL7480.
If the channel is a clock channel, select from
{RISE|FALL}
; otherwise, select from
{HIGH|LOW|DONTCARE}
.
3.8 Communication Commands
:TRIGger:SPI?
Function
Queries all settings related to the trigger.
Syntax
:TRIGger:SPI?
Example
:TRIGGER:SPI? -> :TRIGGER:SPI:
COMBINATION ONLY;SETUP:
SPOLARITY RISE;APATTERN:MODE 0;
BYTE 8;CONDITION TRUE;
PATTERN1 “XXXXXXXX”;
PATTERN2 “XXXXXXXX”;
PATTERN3 “XXXXXXXX”;
PATTERN4 “XXXXXXXX”;
PATTERN5 “XXXXXXXX”;
PATTERN6 “XXXXXXXX”;
PATTERN7 “XXXXXXXX”;
PATTERN8 “XXXXXXXX”;:
TRIGGER:SPI:SETUP:BPATTERN:TRACE 2;
MODE 0;BYTE 8;CONDITION TRUE;
PATTERN1 “XXXXXXXX”;
PATTERN2 “XXXXXXXX”;
PATTERN3 “XXXXXXXX”;
PATTERN4 “XXXXXXXX”;
PATTERN5 “XXXXXXXX”;
PATTERN6 “XXXXXXXX”;
PATTERN7 “XXXXXXXX”;
PATTERN8 “XXXXXXXX”;:TRIGGER:SPI:
SETUP:ABCOUNT FIRSTBYTE;:TRIGGER:
SPI:BCOUNT 0
:TRIGger:SPI:BCOunt
Function
Sets the trigger byte count or queries the
current setting.
Syntax
:TRIGger:SPI:BCOunt {<NRf>|<x>}
:TRIGger:SPI:BCOunt?
<NRf>=0 to 1000
Example
:TRIGGER:SPI:BCOUNT 1
:TRIGGER:SPI:BCOUNT? ->
:TRIGGER:SPI:BCOUNT 1