9.2 List of Parameters
9.2.2 List of Parameters
9-41
9
Parameter Li
s
t
s
*1.
Refer to the following manual for details.
Σ
-7-Series
Σ
-7S SERVOPACK with Analog Voltage/Pulse Train References Product Manual
(Manual No.: SIEP S800001 26)
*2.
Set a percentage of the rated motor torque.
*3.
The setting of Pn502 is used for the stop condition for the motor. Set it to a suitable value for the system.
*4.
These parameters are for SERVOPACKs with a Safety Module. Refer to the following manual for details.
Σ
-V-Series/
Σ
-V-Series for Large-Capacity Models/
Σ
-7-Series User’s Manual Safety Module
(Manual No.: SIEP C720829 06)
*5.
Normally set this parameter to 0. If you use an External Regenerative Resistor, set the capacity (W) of the Exter-
nal Regenerative Resistor.
*6.
The upper limit is the maximum output capacity (W) of the SERVOPACK.
*7.
These parameters are for SERVOPACKs with the Dynamic Brake Option. Refer to the following manual for
details.
Σ
-7-Series AC Servo Drive
Σ
-7S/
Σ
-7W SERVOPACK with Dynamic Brake Hardware Option Specifications Prod-
uct Manual (Manual No.: SIEP S800001 73)
Pn643
2
Homing Direction
0000h to
0001h
–
0000h
All
Immedi-
ately
–
–
Pn644
4
Homing Movement
Speed
1 to
199,999,999
1,000
refer-
ence
units/
min
-1
1000
All
Immedi-
ately
Setup
Pn646
4
Origin Approach Speed
1 to
199,999,999
1,000
refer-
ence
units/
min
-1
1000
All
Immedi-
ately
Setup
Pn648
4
Homing Creep Speed
1 to
199,999,999
1,000
refer-
ence
units/
min
-1
1000
All
Immedi-
ately
Setup
Pn64A
4
Homing Final Travel
Distance
-1,073,741,823
to
+1,073,741,823
Refer-
ence
units
0
All
Immedi-
ately
Setup
Pn64C
2
ZONE Signal Setting
0000h to
0001h
–
0000h
All
After
restart
Setup
–
Pn64D
2
Reserved parameter (Do
not change.)
–
–
0000
–
–
–
–
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Homing Direction
Reference
0
When the /HOME signal turns ON, homing is performed in the
forward direction.
1
When the /HOME signal turns ON, homing is performed in the
reverse direction.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
ZONE Signal Setting
Reference
0
When the control power supply is turned ON or the SERVOPACK
is reset, the /POUT0 to /POUT2 signals are inactive.
1
When the control power supply is turned ON or the SERVOPACK
is reset, the /POUT0 to /POUT2 signals are used as ZONE sig-
nals.
n.
X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)