![YASKAWA SGD7S-R70A Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/yaskawa/sgd7s-r70a/sgd7s-r70a_product-manual_3477694070.webp)
6.1 Control Method Selection
6-2
6.1
Control Method Selection
To perform operation with the program table or jog speed table, set Pn000 (Control Method
Selection) to n.
1
.
Pn000 = n.
X
Control Method
Outline
Reference
n.
1
(default setting)
Position control
Commands from the program table and
jog speed table are used to control
machine positioning.
Operation is also possible by combining program table operation and jog speed table opera-
tion with speed control, position control, or torque control. You can perform the optimum
operation for the application.
To combine different types of control, you set the control method in Pn000 = n.
X
(Con-
trol Method Selection) as shown in the following table.
Note: 1. Before you change between program table operation and another form of control (speed control,
position control, or torque control), confirm that all commands and the motor have stopped.
2. If you use program table operation, do not set Pn000 to n.
3
to n.
B
.
Information
Pn000 = n.
X
Control Method
Reference
n.
0
Speed control (with analog voltage) and
program table operation
Σ
-7-Series
Σ
-7S SERVOPACK
with Analog Voltage/Pulse Train
References Product Manual
(Manual No.: SIEP S800001 26)
n.
1
(default setting)
Position control (with pulse train) and
program table operation
n.
2
Torque control (with analog voltage) and
program table operation