![YASKAWA SGD7S-R70A Скачать руководство пользователя страница 205](http://html1.mh-extra.com/html/yaskawa/sgd7s-r70a/sgd7s-r70a_product-manual_3477694205.webp)
9.2 List of Parameters
9.2.2 List of Parameters
9-5
9
Parameter Li
s
t
s
Pn001
2
Application Function
Selections 1
0000h to
1142h
–
0000h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Motor Stopping Method for Servo OFF and Group 1 Alarms
Reference
0
Stop the motor by applying the dynamic brake.
*1
1
Stop the motor by the applying dynamic brake and then release
the dynamic brake.
2
Coast the motor to a stop without the dynamic brake.
n.
X
Overtravel Stopping Method
Reference
0
Apply the dynamic brake or coast the motor to a stop (use the
stopping method set in Pn001 = n.
X).
*1
1
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then servo-lock the motor.
2
Decelerate the motor to a stop using the torque set in Pn406 as
the maximum torque and then let the motor coast.
3
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then servo-lock the motor.
4
Decelerate the motor to a stop using the deceleration time set in
Pn30A and then let the motor coast.
n.
X
Main Circuit Power Supply AC/DC Input Selection
Reference
0
Input AC power as the main circuit power supply using the L1, L2,
and L3 terminals (do not use shared converter).
*1
1
Input DC power as the main circuit power supply using the B1/
and
2 terminals or the B1 and
2 terminals (use an external
converter or the shared converter).
n.X
Warning Code Output Selection
Reference
0
Output only alarm codes on the /ALO1, /ALO2, and /ALO3 termi-
nals.
*1
1
Output both warning codes and alarm codes on the /ALO1,
/ALO2, and /ALO3 terminals. However, while an warning code is
being output, the ALM (Servo Alarm) output signal will remain ON
(normal state).