9.2 List of Parameters
9.2.2 List of Parameters
9-9
9
Parameter Li
s
t
s
Pn008
2
Application Function
Selections 8
0000h to
7121h
–
0000h
Rotary
After
restart
Setup
–
Pn009
2
Application Function
Selections 9
0000h to
0121h
–
0010h
All
After
restart
Tuning
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
Low Battery Voltage Alarm/Warning Selection
Reference
0
Output alarm (A.830) for low battery voltage.
*1
1
Output warning (A.930) for low battery voltage.
n.
X
Function Selection for Undervoltage
Reference
0
Do not detect undervoltage.
*1
1
Detect undervoltage warning and limit torque at host controller.
2
Detect undervoltage warning and limit torque with Pn424 and
Pn425 (i.e., only in SERVOPACK).
n.
X
Warning Detection Selection
Reference
0
Detect warnings.
*1
1
Do not detect warnings except for A.971.
n.X
Reserved parameter (Do not change.)
n.
X
Reserved parameter (Do not change.)
n.
X
Current Control Mode Selection
Reference
0
Use current control mode 1.
*1
1
•
SERVOPACK Models SGD7S-R70A, -R90A, -1R6A, -2R8A,
-3R8A, -5R5A, and -7R6A: Use current control mode 1.
•
SERVOPACK Models SGD7S-120A, -180A, -200A, -330A,
-470A, -550A, -590A, and -780A: Use current control mode 2.
2
Use current control mode 2.
n.
X
Speed Detection Method Selection
Reference
0
Use speed detection 1.
*1
1
Use speed detection 2.
n.X
Reserved parameter (Do not change.)