![YASKAWA SGD7S-R70A Скачать руководство пользователя страница 187](http://html1.mh-extra.com/html/yaskawa/sgd7s-r70a/sgd7s-r70a_product-manual_3477694187.webp)
8.2 Warning Displays
8.2.3 INDEXER Warning Displays and Troubleshooting
8-47
8
Maintenance
8.2.3
INDEXER Warning Displays and Troubleshooting
INDEXER warning displays and corrections for them are given in the following table.
Error No.
Alarm
Number
Error Name
Meaning
Corrective Action
E41E
A.9F9
Program Table
Save Failure Error
While writing data to the flash memory, a
failure occurred during one of the following
operation.
•
While saving a program table by using
Fn060
•
While initializing a program table by using
Fn063
Repair the hard-
ware.
E42E
A.9F9
ZONE Table Save
Failure Error
While writing data to the flash memory, a
failure occurred during one of the following
operation.
•
While saving a ZONE table by using
Fn061
•
While initializing a ZONE table by using
Fn064
Repair the hard-
ware.
E43E
A.9F9
JOG Speed Table
Save Failure Error
While writing data to the flash memory, a
failure occurred during one of the following
operation.
•
While saving a JOG speed table by using
Fn061
•
While initializing a JOG speed table by
using Fn065
Repair the hard-
ware.
E44E
A.9F9
Canceled Pro-
gram Table Error
There was a request to start program table
operation even though an E19A or E1BA
alarm occurred when the control power
supply was turned ON.
Remove the
cause of the
alarm.
E46E
A.9F9
Canceled JOG
Speed Table Error
There was a request to start JOG speed
table operation even though an E1FA or
E22A alarm occurred when the control
power supply was turned ON.
Remove the
cause of the
alarm.
E4BE
A.9F9
Moving Disabled
Error due to P-OT
Travel in the forward direction was
requested when P-OT was in effect. (For-
ward movement is disabled when P-OT
(forward overtravel) is in effect.)
•
When P-OT is
being used,
move to a posi-
tion where the
P-OT is not in
effect.
•
When P-OT is
not being used,
disable P-OT in
the parameter.
E4CE
A.9F9
Moving Disabled
Error due to N-OT
Travel in the reverse direction was
requested when N-OT was in effect.
(Reverse movement is disabled when N-OT
(reverse overtravel) is in effect.)
•
When N-OT is
being used,
move to a posi-
tion where the
N-OT is not in
effect.
•
When N-OT is
not being used,
disable N-OT in
the parameter.
Continued on next page.