6.2 I/O Signal Allocations
6.2.1 Input Signal Allocations
6-3
6
S
etting
s
6.2
I/O Signal Allocations
Functions are allocated to the pins on the I/O signal connector (CN1) in advance. You can
change the allocations and the polarity for some of the connector pins. Function allocations
and polarity settings are made with parameters.
This section describes the I/O signal allocations.
6.2.1
Input Signal Allocations
Changing Input Signal Allocations
Input Signals That Can Be Allocated to CN1-40 to CN1-46
The input signals that you can allocate to the pins on the I/O signal connector (CN1) and the
related parameters are given in the following table.
•
If you change the polarity of the /S-ON (SERVO ON Input) signal from the default setting, you
will not be able to turn OFF the main circuit power supply to the Servomotor if signal lines break
or other problems occur. If you change the polarity of this signal, verify operation and make
sure that no safety problems will exist.
•
If you allocate two or more signals to the same input circuit, a logical OR of the inputs will be
used and all of the allocated signals will operate accordingly. This may result in unexpected
operation.
Input Signal
Input Signal Name
Parameter
/S-ON
Servo ON
Pn50A = n.
X
/P-CON
Proportional Control
Pn50A = n.
X
P-OT
Forward Drive Prohibit
Pn50A = n.X
N-OT
Reverse Drive Prohibit
Pn50B = n.
X
/ARM-RST
Alarm Reset
Pn50B = n.
X
/P-CL
Forward External Torque Limit
Pn50B = n.
X
/N-CL
Reverse External Torque Limit
Pn50B = n.X
/SPD-D
Motor Direction
Pn50C = n.
X
/SPD-A
Internal Set Speed Selection
Pn50C = n.
X
/SPD-B
Internal Set Speed Selection
Pn50C = n.
X
/C-SEL
Control Selection
Pn50C = n.X
/ZCLAMP
Zero Camping
Pn50D = n.
X
/INHIBIT
Reference Pulse Inhibit
Pn50D = n.
X
/G-SEL
Gain Selection
Pn50D = n.
X
/P-DET
Polarity Detection
Pn50D = n.X
SEN
Absolute Data Request
Pn515 = n.
X
/PSEL
Reference Pulse Input Multiplication
Switch
Pn515 = n.
X
FSTP
Forced Stop
Pn516 = n.
X
/MODE 0/1
Mode Switch
Pn630 = n.
X
/START-STOP
Program Table Operation Start-Stop
Pn630 = n.
X
/HOME
Homing
Pn630 = n.
X
/PGMRES
Program Table Operation Reset
Pn630 = n.X
/SEL0
Program Step Selection Input 0
Pn631 = n.
X
/SEL1
Program Step Selection Input 1
Pn631 = n.
X
/SEL2
Program Step Selection Input 2
Pn631 = n.
X
/SEL3
Program Step Selection Input 3
Pn631 = n.X
Continued on next page.
Important