9.2 List of Parameters
9.2.2 List of Parameters
9-35
9
Parameter Li
s
t
s
Pn630
2
Input Signal Selections
10
0000h to
FFFFh
–
6221h
All
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Siz
e
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
X
/MODE 0/1 (Mode Switch Input) Signal Allocation
Reference
0
Mode 0 is used when CN1-40 input signal is ON (closed).
1
Mode 0 is used when CN1-41 input signal is ON (closed).
2
Mode 0 is used when CN1-42 input signal is ON (closed).
3
Mode 0 is used when CN1-43 input signal is ON (closed).
4
Mode 0 is used when CN1-44 input signal is ON (closed).
5
Mode 0 is used when CN1-45 input signal is ON (closed).
6
Mode 0 is used when CN1-46 input signal is ON (closed).
7
The signal always specifies mode 0.
8
The signal always specifies mode 1.
9
Mode 0 is used when CN1-40 input signal is OFF (open).
A
Mode 0 is used when CN1-41 input signal is OFF (open).
B
Mode 0 is used when CN1-42 input signal is OFF (open).
C
Mode 0 is used when CN1-43 input signal is OFF (open).
D
Mode 0 is used when CN1-44 input signal is OFF (open).
E
Mode 0 is used when CN1-45 input signal is OFF (open).
F
Mode 0 is used when CN1-46 input signal is OFF (open).
n.
X
/START-STOP (Program Table Operation Start-Stop Input) Signal Alloca-
tion
Reference
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
The signal is always active.
8
The signal is always inactive.
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
n.
X
/HOME (Homing Input) Signal Allocation
Reference
0 to F
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.
n.X
/PGMRES (Program Table Operation Reset Input) Signal Allocation
Reference
0 to F
The settings are the same as for /START-STOP (Program Table
Operation Start-Stop Input) Signal Allocation.