11.1 List of Servo Parameters
11.1.2 List of Servo Parameters
11-28
Pn595
2
/EXT3 (External Latch
Input 3) Signal Alloca-
tion
0000h to
2019h
–
Axis A:
1008h,
Axis B:
1014h
All
After
restart
Setup
–
Pn597
2
FSTP (Forced Stop
Input) Signal Allocation
0000h to
3019h
–
0000h
All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
XXX
Allocated Pin Number
000 to 005
The signal is always inactive.
006
Allocate the signal to CN1-6.
007
Allocate the signal to CN1-7.
008
Allocate the signal to CN1-8.
009 to 011
The signal is always inactive.
012
Allocate the signal to CN1-12.
013
Allocate the signal to CN1-13.
014
Allocate the signal to CN1-14.
n.X
Polarity Selection
0
The signal is always inactive.
1
Active when input signal is ON (closed).
2
Active when input signal is OFF (open).
n.
XXX
Allocated Pin Number
003
Allocate the signal to CN1-3.
004
Allocate the signal to CN1-4.
005
Allocate the signal to CN1-5.
006
Allocate the signal to CN1-6.
007
Allocate the signal to CN1-7.
008
Allocate the signal to CN1-8.
009
Allocate the signal to CN1-9.
010
Allocate the signal to CN1-10.
011
Allocate the signal to CN1-11.
012
Allocate the signal to CN1-12.
013
Allocate the signal to CN1-13.
014
Allocate the signal to CN1-14.
n.X
Polarity Selection
0
Set the signal to always enable drive (always disable forcing the motor to
stop).
1
Enable drive when the input signal is ON (closed).
2
Enable drive when the input signal is OFF (open).
3
Set the signal to always prohibit drive (always force the motor to stop).