2.4 Mounting Interval
2.4.1 Installing One SERVOPACK in a Control Panel
2-5
2
In
s
tallation
2.4
Mounting Interval
2.4.1
Installing One SERVOPACK in a Control Panel
Provide the following spaces around the SERVOPACK.
*
For this dimension, ignore items protruding from the main body of the SERVOPACK.
2.4.2
Installing More Than One SERVOPACK in a Control
Panel
Provide the following spaces around the SERVOPACK.
*
For this dimension, ignore items protruding from the main body of the SERVOPACK.
The space required on the right side of a SERVOPACK (when looking at the SERVOPACK from
the front) depends on the SERVOPACK models. Refer to the following table.
3
0 mm min.
3
0 mm min.
40 mm min.
*
40 mm min.
S
ERVOPACK
Install cooling fans above the SERVOPACKs so that hot spots do not occur around the SERVO-
PACKs. Provide sufficient intervals and spaces as shown in the following figure to enable cooling
by the fans and natural convection.
SERVOPACK Model
Space on
Right Side
Cooling Fan Installation Conditions
10 mm above SERVOPACK’s Top Surface
SGD7C-1R6A, -2R8A, -5R5A, and -7R6A
5 mm min.
Air speed: 1.0 m/s min.
Important
Fan
3
0 mm min.
Thi
s
di
s
tance depend
s
on the model.
3
0 mm min.
Fan
40 mm min.*
40 mm min.
S
ER
VOP
ACK
S
ER
VOP
ACK
S
ER
VOP
ACK
S
ER
VOP
ACK