4.3 Self Configuration
4.3.3 Confirming the Detailed Definitions of the Function Modules
4
Pr
eparation
s
4-37
DEVICE
Sets the slave model.
•
Link Assignment Model Details
The relationship between the model displayed under
DEVICE
and its corresponding profile is
shown below.
If you manually assign a link, be sure that the actual device connected to the SVC4 is the
same as the one that is displayed under
DEVICE
on the Link Assignment Tab Page.
PROFILE
Set the profile to use.
•
Settings: Depends on the device.
BYTE
Set the number of transmission bytes.
•
Settings: Depends on the profile.
INPUT
Sets the first register address of the input area.
These settings are disabled if the profile is set to
Standard Servo
.
•
Setting range: The range of the Module’s I/O registers
OUTPUT
Sets the first register address of the output area.
These settings are disabled if the profile is set to
Standard Servo
.
•
Setting range: The range of the Module’s I/O registers
D
Enable or disable the I/O registers.
•
Settings: Enable or Disable
:
Enabled
:
Disabled
DEVICE
Communications Specifications
Corresponding
Profile
Number of Trans-
mission Bytes
Minimum Trans-
mission Cycle
Maximum Trans-
mission Cycle
SGD7S-
20
Standard Servo
32 or 48
125
μ
s
4 ms
SGD7W-
20
SGDV-
2
JAPMC-MC2320-E
Standard I/O
16, 32, 48, or 64
250
μ
s
32 ms
JEPMC-MTD2310-E
Standard I/O
16
250
μ
s
8 ms
JEPMC
−
MTA2900
−
E
Standard I/O
32
125
μ
s
8 ms
JEPMC
−
MTA2910
−
E
Standard I/O
16
125
μ
s
8 ms
JEPMC
−
MTP2900
−
E
Standard I/O
64
125
μ
s
8 ms
JEPMC
−
MTP2910
−
E
Standard I/O
64
125
μ
s
8 ms
WildCard Device
Standard Servo
48
Depends on the
actual device.
Depends on the
actual device.
Standard I/O
16, 32, 48, or 64
Depends on the
actual device.
Depends on the