6.4 Trial Operation with the SVD
6-10
5.
Set the following items, which are necessary for trial operation.
6.
Save the settings that you made in step 5 in the SERVOPACK.
Save the servo parameters online.
Write the fixed parameters.
7.
To enable changes to the settings, place the MPE720 offline, and then turn the power
supply to the SERVOPACK OFF and ON again.
8.
Place the the MPE720 back online, and open the Module Configuration Definition Tab
Page.
9.
Double-click the axis for which to preform trial operation.
10.
Display the setting parameters.
11.
Turn ON the servo in
Run command setting
.
The Servomotor can now be operated.
12.
Operate the Servomotor at low speed.
Trial Operation for Positioning
16: Position reference setting: 10,000 (for an absolute encoder, add 10,000 to the current position)
28: Speed reference setting = 40
8: Positioning
13.
While operation is in progress for step 12, confirm the following items.
Note: If the load machine is not sufficiently broken in before trial operation, the Servomotor may become over-
loaded.
Setting
Reference
Electronic Gear Settings
Motor Direction Selection
Overtravel
5.11 Overtravel Function and Settings
Confirmation Item
Reference
Confirm that the rotational direction of the Servomotor
agrees with the forward or reverse reference. If they
do not agree, correct the rotation direction of the Ser-
vomotor.
Confirm that no abnormal vibration, noise, or tem-
perature rise occurs. If any abnormalities are found,
implement corrections.
Σ
-7-Series
Σ
-7C SERVOPACK Troubleshooting Man-
ual (Manual No.: SIEP S800002 07)