8.10 Vibration Suppression
8.10.3 Operating Procedure
8-56
4.
Click the
Set
Button.
If the vibration is not eliminated, use the
▲
and
▼
Buttons for the set frequency to fine-tune the value
and click the
Set
Button again.
Click the
Reset
Button during adjustment to restore the setting to its original value. The status from
before when adjustment was started will be restored.
5.
When the vibration has been eliminated, click the
Finish
Button.
The updated value will be saved in the SERVOPACK.
This concludes the procedure to set up vibration suppression.
No settings related to vibration suppression are changed during operation.
If the Servomotor does not stop within approximately 10 seconds after changing the setting,
an update timeout will occur. The setting will be automatically returned to the previous value.
Vibration suppression will be enabled in step 5. The Servomotor response, however, will change
when the Servomotor comes to a stop with no reference input.
Important
Important