HW0482309
94
2. Output of Current for the Resistance Measurement
CAUTION
•
Do not touch the power cable, torch, or jig stand while current for the
resistance measurement is being output.
Failure to observe this caution may result in electric shock.
(1)
Record the value of “C.08” parameter in advance since the result of the measurement
is over written.
(2)
Press the “Record” button for 3 seconds or more.
The constant current is output for measurement of the resistance, and power is
supplied to the power cable that is to be an external resistance path.
The conduction lasts for approximately 10 seconds and completes automatically.
After the output, the resistance is measured and its result is stored in the “C.08”
parameter.
Fig. 14.2.2.2 Current Output for Measurement of Resistance
-
Press the “Record” button again to stop the output during conduction, however
the resistance is not measured.
-
When the cable for resistance measurement or the power cable, etc. is not
connected, the ammeter displays 0 A. Confirm the connection path.
P.R.M. Select
P.R.M. Set
Weld. Type
Common PRM select
Record
Gas
User File Select
−
File No.1
V
V/Set
A W/S
+
L
R
抵抗値測定モードを表す
−r−
A W/S
−
File No.3
-
−
Search
A
Wire m/min
−
Warning
−
Power
−
File No.2
Type
BY pressing the “Record” button for 3 seconds or
more, the LED indicator lamp above the “Record”
button lights to start conduction.
During conduction, “0.0” is displayed on the
Wire meter and approximately 300A current is
output without motor rotation. The voltmeter or
ammeter displays voltage or current during
conduction.